Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 16 AWG solid or stranded round. |
|
Insulation | Extruded FRPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Assembly | Two conductors or groups may be laid parallel or twisted together. Three or more conductors or groups shall be twisted together. Lay of insulated conductors or groups not specified. Barrier layer and/or fillers optional. |
|
Shield | Optional. Over one or more conductors. |
|
Jacket | Extruded PVC |
| dia of cable under jacket |
| 0.700 inches or less | 30 mils minimum average thickness | 24 mils minimum thickness at any point |
| 0.701-1.000 dia | 60 avg | 48 min |
| 1.001-1.500 dia | 80 avg | 64 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnect of electronic equipment. |
|