APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20241 Issued:1983-01-07
Revised:2019-11-07
Style 20241 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round.
InsulationExtruded FRPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo conductors or groups may be laid parallel or twisted together. Three or more conductors or groups shall be twisted together. Lay of insulated conductors or groups not specified. Barrier layer and/or fillers optional.
ShieldOptional. Over one or more conductors.
JacketExtruded PVC
dia of cable under jacket
0.700 inches or less30 mils minimum average thickness24 mils minimum thickness at any point
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnect of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024