APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20242 Issued:1983-01-21
Revised:2012-03-20
Style 20242 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to four conductors. All individually insulated wires cabled together with length of lay of the twisted wires not specified. Fillers and/or barrier layer optional. Manufacturer shall maintain a record of individual styles used within the cable. May use mixed AWG and styles within the same cable.
JacketExtruded PVC, 23 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024