APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20245 Issued:1983-05-20
Revised:2012-12-28
Style 20245 Multi-conductor Cable with Extruded Non-Integral Jacket

Rating60 deg C, 150 Vac, 300 Vac peak, Horizontal Flame.
Conductor33 - 18 AWG. Solid, stranded or tinsel.
InsulationExtruded PVC, 7 mils minimum average thickness, 5 mils minimum thickness at any point.
Assembly2 - 10 conductors. May include mixed AWG sizes. Cable may be either straight or wound in retractile form (Coiled cable). Core may be either flat or round. Barrier layer and/or fillers optional.
ShieldOptional. One or more insulated conductors may be shielded.
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal cable of electronic equipment, or as "Handset Wire or Telephone Cord for Subscriber Sets".