Rating | 80 deg C, 300 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded FEP |
| dia of cable under jacket |
| 0.425 inches or less | (const A) | 10 mils min average | 8 mils minimum at any point |
| dia of cable under jacket of 0.425 or less | (const B) | 20 avg | 16 min |
| 0.426-0.700 dia | (const A) | 10 avg | 8 min |
| 0.426-0.700 dia | (const B) | 30 avg | 24 min |
| 0.701-1.500 dia | (const A) | 20 avg | 16 min |
| 0.701-1.500 dia | (const B) | 40 avg | 32 min |
| 1.501-2.500 dia | (const A) | 30 avg | 24 min |
| 1.501-2.500 dia | (const B) | 50 avg | 40 min |
| 2.501 dia and larger | (const A) | 30 avg | 24 min |
| 2.501 dia and larger | (const B) | 60 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A Internal wiring of appliances, and electronic equipment. Construction AB Internal or external wiring of appliances and electronic equipment. |
|