APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2025
Issued:
1959-05-01
Revised:
2008-05-27
Style
2025
Two-Conductor Style SPT-3 Cord.
Rating
90 deg C, 300 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor
14 AWG - 10 AWG consisting of No. 30 AWG or smaller stranded, tinned or bare copper.
Insulation
Integral with Jacket. PVC, 80 mils min average, 72 mils minimum at any point.
Assembly
Two conductor, same as SPT-3.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring of room cooler units where ripped not more than three inches and where exposed to temperatures not exceeding 90 deg C; or Internal Wiring of Remote Outdoor Condensing units for Domestic Cooling Systems where exposed to temperatures not exceeding 90 deg C. Either marking may also add where applicable dependent upon the compount use: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C; whichever is applicable). Polarity identification may be omitted.
UL and the UL Logo are trademarks of UL LLC © 2024