APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2025 Issued:1959-05-01
Revised:2008-05-27
Style 2025 Two-Conductor Style SPT-3 Cord.

Rating90 deg C, 300 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor14 AWG - 10 AWG consisting of No. 30 AWG or smaller stranded, tinned or bare copper.
InsulationIntegral with Jacket. PVC, 80 mils min average, 72 mils minimum at any point.
AssemblyTwo conductor, same as SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units where ripped not more than three inches and where exposed to temperatures not exceeding 90 deg C; or Internal Wiring of Remote Outdoor Condensing units for Domestic Cooling Systems where exposed to temperatures not exceeding 90 deg C. Either marking may also add where applicable dependent upon the compount use: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C; whichever is applicable). Polarity identification may be omitted.
 
UL and the UL Logo are trademarks of UL LLC © 2024