APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
20250
Issued:
1983-02-17
Revised:
2008-05-27
Style
20250
Insulated Wire
Rating
60 deg. C, 30Vac, Horizontal flame
Conductor
18 AWG min., solid or stranded round, tinned or bare copper.
Insulation
Labeled or complying with manufacturer's AWM procedure, or Listed fixture wire 18 AWG or larger.
Assembly
Two to four insulated conductors cabled together, with or without fillers.
Covering
15 mils min average, 13 mils min at any point of extruded thermoplastic (PVC) or glass braid (treated or untreated).
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
As nonenclosed visible wires for fixtures other than lamp-supported lampholders, or enclosed wiring in fixtures where the acceptability of the combination is determined by Underwriters Laboratories Inc.