APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20251 Issued:1983-02-23
Revised:2012-04-13
Style 20251 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 150 Vac, 300 V peak, Horizontal flame.
Conductor33 AWG - 18 AWG, solid, stranded. May include mixed AWG sizes.
Insulationextruded PP, 7 mils minimum average, 5 mils minimum at any point.
AssemblyTwo to ten insulated conductors. Cable may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and/or fillers optional.
ShieldOptional. One or more insulated conductors may be shielded.
Jacketextruded PVC, 20 mils minimum average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal cable of electronic equipment, or as "Handset Wire or Telephone Cord for Subscriber Sets".

UL and the UL Logo are trademarks of UL LLC © 2024