| Rating | 80 deg C, 600 Vac, Horizontal flame. |
|
| Conductor | 36 AWG - 12 AWG, solid or stranded. |
|
| Insulation | Extruded PE or extruded FRPE, 30 mils min average, 27 mils minimum at any point. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. |
|
| Shield | Optional. |
|
| Covering | Optional -A 6 mil or heavier extruded PVC covering may be extruded over the conductor assembly. |
|
| Jacket | Extruded PVC |
| dia of cable under jacket |
| 0.700 inches or less* | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| *Major dia if cable is flat or oval. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of electronic equipment. |
|