APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20260 Issued:1983-04-15
Revised:2012-07-03
Style 20260 Flat ribbon cable

Rating80 deg C, 30 Vac, Horizontal Flame, VW-1 Flame.
ConductorMinimum 40 AWG. Same or mixed conductor size.
InsulationLabeled Style 1691.
Assembly2-300 conductors. May be bonded together or heat bonded between 2 sheets FEP film, min 0.5 mil thick. May have bond intervals.
CoveringOptional. FEP film, minimum 0.5 mil thick, on both sides.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of low energy non-hazardous circuits in audio and video equipment.