Rating | 60 deg C, 30 Vac, Cable flame. |
|
Conductor | 36 AWG - 16 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | PP or PVC or TPE or Polyamide, wall thickness may vary from 3.5 min at any point to 10 mils max or Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Two to fifty individual conductors, different conductor sizes may be used in one cord. Two conductors may be laid parallel or twisted together. Three or more conductors shall be twisted together. Lay of insulated conductors not specified, but with a twist opposite in direction to the direction in which the helical cord is wound. Cable may be either straight or coiled in the form of a helix. |
|
Shield | Optional. |
|
Jacket | PVC |
| dia of cable under jacket |
| 0.425 inches or less | 30 mils min average | 24 mils minimum at any point |
| 0.426-0.700 dia | 45 avg | 36 min |
| 0.701-1.000 dia | 60 avg | 48 min |
| 1.001-1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment in Class 2 or 3 circuits (such as computers and business machines). |
|