APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20263 Issued:1983-04-27
Revised:2019-11-07
Style 20263 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Cable flame.
Conductor36 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationPP or PVC or TPE or Polyamide, wall thickness may vary from 3.5 min at any point to 10 mils max or Labeled or complies with manufacturer's AWM Procedure.
AssemblyTwo to fifty individual conductors, different conductor sizes may be used in one cord. Two conductors may be laid parallel or twisted together. Three or more conductors shall be twisted together. Lay of insulated conductors not specified, but with a twist opposite in direction to the direction in which the helical cord is wound. Cable may be either straight or coiled in the form of a helix.
ShieldOptional.
JacketPVC
dia of cable under jacket
0.425 inches or less30 mils min average24 mils minimum at any point
0.426-0.700 dia45 avg36 min
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment in Class 2 or 3 circuits (such as computers and business machines).

UL and the UL Logo are trademarks of UL LLC © 2024