APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20266 Issued:1983-05-17
Revised:2019-11-07
Style 20266 Multiple Conductor Cable with Extruded Non-intergal Jacket.

Rating80 deg C, 150 Vac, Cable flame.
InsulationLabeled or comply with Manufacturer's Procedure.
AssemblyPVC jacketed cable containing flat ribbon cable folded or spiraled layers, with or without additional insulated singles.
ShieldOptional.
JacketExtruded PVC
dia of cable under jacket
0.700 inches or less*30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.101-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment or internal or external wiring for electric machinery or equipment where not subject to mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2024