APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20275 Issued:1983-08-11
Revised:2012-04-06
Style 20275 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 150 V, 300 V peak, Cable flame.
ConductorTwo to ten 18 - 33 AWG tinned or bare, stranded copper (round or tinsel), may include mixed AWG sizes.
InsulationExtruded TPE, 7 mils min average, 5 mils min at any point.
ShieldOptional - One or more conductor or groups of conductors may be shielded.
JacketExtruded PVC, 25 mils min average, 20 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseA. "External interconnection of electronic equipment where the overall length does not exceed 5 ft." or B. "External interconnection of electronic equipment where not routed along walls, floor, or other abuse areas."

UL and the UL Logo are trademarks of UL LLC © 2024