Rating | 125 deg C, 240 Vac, Horizontal flame. |
|
Conductor | 16 AWG stranded nickel coated copper, solid or stranded round, tinned or bare copper. Conductive Core - Extruded, polyvinylidene fluoride compound filled with special carbon, 14 mils min. average, 8 mils at any point, dimensions of conductive core: approx. 80 mils height by 315 to 440 mils width. |
|
Insulation | Extruded ETFE, 14 mils min average, 13 mils minimum at any point. |
|
Assembly | Two conductors; Conductive core over conductor. |
|
Shield | Optional. |
|
Jacket | Optional - Extruded ETFE, 12 mils min average, 10 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe Heating Cable where the acceptability of the combination is to be determined by UL. |
|