Rating | 80 deg C, 300 Vac, Cable flame. |
|
Conductor | 36 - 12 AWG, solid or stranded. |
|
Insulation | Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Two to fifty conductors; different conductor sizes may be used in one cord. Two to eight conductors may be laid parallel or twisted together. Nine or more conductors shall be twisted together. Lay of insulated conductors not specified, but with a twist opposite in direction to the direction in which the helical cord in wound. Cable may be either straight or coiled or in the form of a helix. |
|
Shield | Optional. |
|
Jacket | extruded TPU |
| Diameter of cable under jacket in inches | Minimum average thickness in mils | Minimum thickness at any point in mils |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 40 | 36 |
| 1.001-1.500 | 60 | 48 |
| 1.501-2.500 | 80 | 64 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of appliances or electronic equipment. |
|