APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20285 Issued:1983-10-10
Revised:2012-04-11
Style 20285 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 150 Vac, Horizontal flame.
Conductor33 AWG - 18 AWG, solid or stranded.
InsulationExtruded PP, 7 mils minimum average thickness, 5 mils minimum thickness at any point.
AssemblyTwo to twenty conductors. Cable may be either straight or wound in retractile form. Core may be either flat or round. May include mixed AWG sizes.
ShieldOptional - One or more may be shielded.
CoveringOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal or external wiring. May also be marked "300 Volts peak".

UL and the UL Logo are trademarks of UL LLC © 2024