Rating | 60 deg C, 150 Vac, Horizontal flame. |
|
Conductor | 33 AWG - 18 AWG, solid or stranded. May include mixed AWG sizes. |
|
Insulation | Extruded PE, 7 mils minimum average thickness, 5 mils minimum thickness at any point. |
|
Shield | Optional - One or more may be shielded. |
|
Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
Assembly | Two to thirty conductors; Cable may be either straight or wound in retractile form. Core may be either flat or round. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | "Internal or External Interconnecting Cable of Electronic Equipment." May also be marked "300 Volts peak." |
|