APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20287 Issued:1983-10-10
Revised:2012-07-13
Style 20287 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor33 AWG - 18 AWG solid or stranded round, tinned or bare copper.
InsulationPVC, 7 mils min average, 5 mils min at any point.
AssemblyTwo to twenty conductors; Cable may be either straight or wound in retractile form. Core may be either flat or round. May include mixed AWG sizes.
ShieldOptional - One or more insulated conductors may be shielded.
JacketPVC, 20 mils min average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Cable of Electronic Equipment, or as "Handset Wire or Telephone Cord for Subscriber Sets."