APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20289 Issued:1983-12-01
Revised:2012-05-22
Style 20289 Parallel Cable with Extruded Integral Insulation and Jacket

Rating105 deg C, 30 Vac, Horizontal Flame.
Conductor36 AWG, Solid or Stranded Round.
InsulationExtruded PVC, 5 mils minimum at any point.
AssemblyTwo conductors; The cable consists of two parallel insulated conductors with an overall jacket.
JacketExtruded PVC, 5 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring in Class 2 circuits of Electronic Equipment.