Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 22 AWG - 14 AWG solid or stranded round, tinned or bare copper. Conductive Core - Over the conductor is an extruded semi-conductive high temperature thermoplastic or thermoset covering. |
|
Insulation | FEP or PVDF or TPE or XLPE, 20 mils min average, 18 mils minimum at any point. (See Facing Page for Compound Designations) |
|
Assembly | Two or three conductors. Parallel to the covering 1, 2 or 3 Recognized style may be placed. Cable is constructed of conductor with conductive core, optional inner covering, optional shield, optional jacket, optional outer covering. |
|
Shield | Optional. |
|
Covering | (Optional) Inner- 12 mils min at any point, TPE. (Optional) Outer - 10 mils min at any point, FEP, or 13 mils min at any point, ECTFE. |
|
Braid | Optional. |
|
Jacket | Optional. FEP or PVDF or TPE or XLPE, 20 mils min average, 16 mils minimum at any point. See facing page for compound. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe Heating Cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|