APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20294 Issued:1984-01-10
Revised:2019-11-07
Style 20294 Multiple-conductor cable using non-integral jacket

Rating80 deg C, no voltage assigned, Cable flame.
Conductor40 AWG min. Solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyThe cable consists of two or three groups of insulated conductors (lay of individual conductors not specified). The groups are laid parallel with an overall PVC jacket and may have an interconnecting web.
ShieldEach section may be shielded.
JacketPVC
dia of the cable under jacket
0.500 inches or less*30 mils min average24 mils minimum at any point
0.501-0.750 dia45 avg36 min
0.751-1.000 dia60 avg48 min
*width or thickness of web are not specified
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment in Class 2 or 3 circuits.

UL and the UL Logo are trademarks of UL LLC © 2024