Rating | 80 deg C, no voltage assigned, Cable flame. |
|
Conductor | 40 AWG min. Solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | The cable consists of two or three groups of insulated conductors (lay of individual conductors not specified). The groups are laid parallel with an overall PVC jacket and may have an interconnecting web. |
|
Shield | Each section may be shielded. |
|
Jacket | PVC |
| dia of the cable under jacket |
| 0.500 inches or less* | 30 mils min average | 24 mils minimum at any point |
| 0.501-0.750 dia | 45 avg | 36 min |
| 0.751-1.000 dia | 60 avg | 48 min |
| *width or thickness of web are not specified |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment in Class 2 or 3 circuits. |
|