APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20297 Issued:1984-01-18
Revised:2012-07-25
Style 20297 Flat Ribbon Cable.

Rating105 deg C, 150 Vac, 300 Vac, Horizontal flame.
Conductor40 AWG - 24 AWG solid or stranded round.
InsulationExtruded TPE, 5 mils min average. See Facing Page for compound.
AssemblyTwo through 150 conductors laid parallel. Top or bottom layers may form ridges over conductors.
ShieldOptional.
CoveringOptional - Extruded PVC, 5 mils min at any point, 80 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.