APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20299 Issued:1984-01-25
Revised:2012-07-24
Style 20299 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure, 3 mils min average.
AssemblyThe cable consists of two or more insulated conductors laid flat and parallel in a single plane with over- all shield and a PVC jacket. A drain wire with a conductive thermoplastic covering may be employed and laid parallel with the insulated conductors. Insulated singles shall not employ black insulation when a black semi-conducting shield is employed.
ShieldOptional.
JacketPVC, 9 mils min average, 7 mil min at any point wall of PVC. Alignment rib may be provided on outside conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024