APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20300 Issued:1984-01-25
Revised:2012-07-26
Style 20300 Laminated flat ribbon label.

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor36 AWG - min solid or stranded round, tinned or bare copper. Same or mixed AWG. Material not specified.
InsulationPVC, 2 mils min average, 2 mils min. at any point. Top or bottom layers may form ridges. Extruded or heat laminated PVC.
AssemblyTwo through 150 laid parallel and in one plane.
ShieldOptional.
CoveringOptional - PVC, 5 mils min. at any point, 80 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in Class 2 circuits of electronic computers and business machines.