APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20304 Issued:1984-02-16
Revised:2012-03-22
Style 20304 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, voltage not specified, Horizontal flame.
Conductor38 AWG - 18 AWG solid or stranded.
InsulationExtruded Polyester, 7 mils minimum average thickness, 5 mils minimum thickness at any point.
AssemblyTwo to ten conductors. Cable may be either straight or wound in retractile form. Core may be either flat or round.
ShieldOptional.
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal cable of electronic equipment, or as "Handset Wire or Telephone Cord for Subscriber Sets".