APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20310 Issued:1984-04-05
Revised:2012-03-27
Style 20310 Multiple-conductor cable using non-integral jacket

Rating60 deg C, no voltage assigned, Horizontal flame.
Conductor18 - 36 AWG, stranded copper (round or tinsel).
InsulationExtruded TPEEE, TPE, PBE, HDPE, TPEE, PBT or PP, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
Assembly2 to 10 conductors. Cable may be either straight or wound in retractile form. Core may be either flat or round.
ShieldOptional.
CoveringOptional - Polyester, 2 mils minimum thickness at any point.
JacketExtruded PVC, 13 mils minimum average thickness, 11 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs "Handset Wire or Telephone Cord for Subscriber Sets".