APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20314 Issued:1984-04-23
Revised:2011-12-07
Style 20314 Parallel cable with extruded integral insulation and jacket

Rating60, 75, 80, 90, 105 deg C, 600 Vac, Horizontal flame.
Conductor28 AWG - 10 AWG, solid or stranded.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo to four conductors, similar to Type SPT except that the insulation is a nominal 30 mils and the min acceptable thickness and at any point before and after separation is 13 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.