Rating | 80 deg C, 300 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two to eight insulated conductors laid flat or two or more twisted singles or groups of twisted singles, may be twisted together or groups may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Cable may be either straight or wound in retractile form. |
|
Shield | Optional. |
|
Covering | Optional - A 10 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | PUR |
| dia of cable under jacket |
| 0.700 inches or less* | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501-4.000 dia | 110 avg | 88 min |
| 4.001 dia and larger | 140 avg | 112 min |
| *Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of appliances or electronic equipment. |
|