APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20318 Issued:1984-05-14
Revised:2012-05-22
Style 20318 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating60 deg C, 300 Vac, Cable Flame.
Conductor36 AWG - 16 AWG, Solid or Stranded Round.
InsulationExtruded PP, wall thickness may vary from 3.5 minimum at any point to 30 mils max or Labeled or complies with manufacturer's AWM Procedure.
AssemblyTwo to fifty different conductor sizes may be used in one cord. Cable may be either straight or wound in retractile form. Core may be either flat (max 20 conductors) or round.
ShieldOptional.
JacketExtruded TPU
diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
0.425 or less3024
0.426-0.7004536
0.701-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection or Internal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024