Rating | 90 deg C, 30 Vac, Horizontal Flame (Internal), Cable flame (External). |
|
Conductor | 40 AWG Min. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more twisted insulated singles or groups of twisted insulated singles twisted together. Lay of length not specified. Barrier layer and/or fillers are optional, manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional - May be over one or more of the insulated conductors or applied over the assembly. |
|
Jacket | Extruded TPU. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.425 inch or less | 30 mils | 24 mils |
| 0.426-0.700 | 45 mils | 36 mils |
| 0.701-1.000 | 60 mils | 48 mils |
| 1.001-1.500 | 80 mils | 64 mils |
| 1.501-2.500 | 110 mils | 88 mils |
| 2.501 inch or greater | 140 mils | 112 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As internal wiring or external interconnection of Class 2 circuit electronic equipment (Such as electronic computers and electric business machines). |
|