APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20322 Issued:1984-06-11
Revised:2019-11-07
Style 20322 Multiconductor cable with extruded non-integral jacket.

Rating75 deg C, 600 Vac, Cable flame.
Conductor32 AWG - 4/0 AWG solid or stranded round, tinned or bare copper.
InsulationPVC
32-9 AWG conductor size30 mils min average27 mils minimum at any point
8 AWG45 avg40 min
7-2 AWG60 avg54 min
1-4/0 AWG80 avg72 min
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional - A 10 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPVC
dia of cable under jacket
0.700 inches or less60 mils min average48 mils minimum at any point
0.701-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external interconnections of electronic equipment and appliances.