APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20324 Issued:1984-06-22
Revised:2011-12-30
Style 20324 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 150 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyThe cable consists of two or more insulated conductors laid flat and parallel in a single plane with an overall shield and a PVC jacket. A drain wire with a conductive thermoplastic covering may be employed and laid parallel with the insulated conductors. Insulated singles shall not employ black insulation when a black semi-conducting shield is employed.
ShieldOptional.
JacketPVC, 9 mil min average, 7 mil min at any point wall of PVC. Alignment rib may be provided on outside conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.