APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20325 Issued:1984-06-22
Revised:2012-07-26
Style 20325 Multiple Conductor Flat Cable using Non-Integral Extruded Jacket

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor18 - 14 AWG, Stranded Round.
InsulationLabeled or complying with Manufacturer's AWM procedure.
AssemblyThe cable consists of two or more insulated conductors laid flat and parallel in a single plane or a flat cable, an overall shield and a PVC insulation. A drain wire with a conductive thermoplastic covering may be employed and laid parallel with the insulated conductors. Insulated conductors shall not employ black insulation when a black semi-conducting shield is employed.
ShieldOptional.
JacketExtruded PVC - 9 mil minimum average, 7 mil minimum at any point. Alignment rib may be provided on outside conductors. PVC is Non-Integral.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.