APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20329 Issued:1984-07-24
Revised:2019-11-07
Style 20329 Multiple conductor with extruded insulation.

Rating105 deg C, voltage rating not specified, Cable flame.
Conductor36 AWG min. solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketTPE - See facing page for compound designation
dia of cable under jacket
0.700 inches or less*60 mils min average
0.701-1.500 dia80 avg
1.501-2.500 dia110 avg
2.501 dia and larger140 avg. *Major dia if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024