APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20332 Issued:1984-07-24
Revised:2012-04-17
Style 20332 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Cable flame.
Conductor40 AWG - 16 AWG solid or stranded.
InsulationExtruded Nylon (Polyamide), extruded PP, extruded TPE or extruded PVC, 3.5 mils min thickness at any point, 10 mils maximum thickness, or labeled or complies with manufacturer's AWM procedure.
AssemblyTwo to 50 conductors. Two conductors may be laid parallel or twisted together. Three or more conductors shall be twisted together. Lay of insulated conductors not specified, but with a twist opposite in direction to the direction in which the helical cord is wound. Cable may be either straight or coiled in the form of a helix. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment in Class 2 or 3 circuits (such as computers and business machines).

UL and the UL Logo are trademarks of UL LLC © 2024