APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20333 Issued:1984-07-26
Revised:2012-04-12
Style 20333 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Inner Conductor40 AWG - 18 AWG, solid or stranded.
InsulationInner Layer - Extruded foamed PE or extruded foamed XLPE. Outer Layer - Extruded PE or extruded XLPE. 3 - 100 mils total composite thickness, Two layers are non-separable.
AssemblyTwo conductors.
ShieldOptional.
CoveringOptional - PETP tape or polyester tape, 0.7 mil minimum thickness, applied with minimum 50 percent overlap.
Outer ConductorOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.

UL and the UL Logo are trademarks of UL LLC © 2024