APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20338 Issued:1984-08-21
Revised:2012-02-08
Style 20338 Flat Ribbon Cable

Rating105 deg C, no voltage, Horizontal flame. Optional - 60 or 80 deg C Oil, Gasoline Resistant.
Conductor40 AWG - 18 AWG solid or stranded.
InsulationExtruded PTFE, 8 mils min thickness at any point.
AssemblyTwo-100 conductors laid parallel in one plane. May include mixed sizes.
CoveringExpanded PTFE.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of electronic Equipment in Class 2 Circuits Only. Tags may indicate the following: "Suitable for immersion in gasoline; gasoline vapor; and 60 degrees C or 80 degrees C in oil."