APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20340 Issued:1984-08-20
Revised:2012-04-13
Style 20340 Laminated flat ribbon cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG solid or stranded round.
InsulationLabeled Styles 1007, 1061 or 1095.
AssemblyTwo to 100 insulated singles or twisted pair or triads laid parallel in one plane, retained by heat or film melt bonded section at random intervals from 2 to 100 in apart, with or without PVC bands on one side of the cables in between the heat or film melt bonded sections. Width of heat or film melt bonded sections min 1 in width of PVC bands, approx 3/16 in. Manu- facturer shall maintain a record of all singles used in each cable.
JacketOptional -extruded PVC, 12 mils min average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring

UL and the UL Logo are trademarks of UL LLC © 2024