APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20344 Issued:1984-10-03
Revised:2011-11-25
Style 20344 Parallel cable with extruded integral insulation.

Rating105 deg C, 300 Vac, FT2 flame.
Conductor24 AWG - 18 AWG consisting of 30 AWG or smaller strands.
InsulationExtruded PVC, 45 mils minimum average thickness, 40 mils minimum thickness at any point before separation, 27 mils minimum thickness at any point after separation, 80 mils minimum web thickness.
AssemblySame as for Type SPT-2. Three conductors. Two 18 AWG conductors and one 22 AWG-24 AWG conductor. The two 18 AWG conductors shall be adjacent.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial purpose cord to be used only as a power supply cord for touch control lamps.