APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20349 Issued:1984-10-24
Revised:2013-01-15
Style 20349 Flat Ribbon Cable

Rating80 deg C, 30 Vac, Horizontal Flame.
Conductor40 AWG minimum.
InsulationConsists of two layers. Outer layer: Extruded PVC, 6 mils minimum average thickness, 5 mils minimum thickness at any point. Inner layer: PVC or XLPVC sheets bonded each side of conductors, 26 mils minimum distance between conductors, 6 mils minimum edge width.
Assembly2-50 conductor held parallel in one plane. One or more conductors may be contact with shield.
ShieldOptional.
CoveringOptional. Laminated one or two sheets of PVC, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.