APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20350 Issued:1984-11-07
Revised:2012-12-12
Style 20350 Multiple conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Cable flame.
Conductor40 AWG minimum, solid or stranded.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Manufacturer shall maintain a complete description of each assembly. Cable may be either straight or wound in retractile form.
ShieldOptional - may be over one or more of the insulated conductors or applied over the assembly.
JacketExtruded TPU.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024