APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20355 Issued:1984-11-15
Revised:2012-07-27
Style 20355 Multiple-conductor cable using non-integral jacket.

Rating60, 80 deg C, 30 Vac, Horizontal flame, VW-1.
Conductor40 AWG min, solid or stranded.
InsulationExtruded PE, extruded foamed PE, extruded FRPE, extruded foamed FRPE, extruded PP, extruded foamed PP, extruded PFA, extruded foamed PFA, extruded FEP, extruded foamed FEP, extruded PTFE, extruded foamed PTFE, extruded XLPE, extruded foamed XLPE, extruded XLFRPE, extruded foamed XLFRPE, extruded XLPP, extruded foamed XLPP, extruded XLPFA, extruded foamed XLPFA, extruded XLFEP, extruded foamed XLFEP, extruded XLPTFE, extruded foamed XLPTFE, 5 mils minimum at any point, 125 mils maximum. The insulation may be applied directly over the conductor or applied as a spiral wrapped PE thread (5 mils minimum, 40 mils maximum) and enclosed with "tubed on" insulation.
AssemblyFlat parallel coaxial cable.
CoveringOptional. Extruded PVC, 2 mils minimum, or non-extruded PETP film, 0.5 mils or heavier.
ShieldOptional.
CoveringOptional. Extruded PVC, non-extruded heat sealed PVC tape, extruded Nylon (polyamide), extruded Polyester, extruded PVDF, extruded FEP, extruded PTFE, or non-extruded Lacquered braids, 2 mils minimum at any point, or non-extruded PETP film, non-extruded Polyester-PE laminated film, 0.5 mils or heavier.
ShieldOptional.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point, after rip.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor internal or external interconnections of electronic equipment and/or appliances.

UL and the UL Logo are trademarks of UL LLC © 2024