APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2036 Issued:1959-05-01
Revised:2012-12-11
Style 2036 Parallel cable with extruded integral insulation and jacket

Rating105 deg C, 600 Vac, FT2 Flame. Optional - 60 deg C or 80 deg C Oil.
Conductor14 AWG, 12 AWG or 10 AWG, stranded, consists of 30 AWG or smaller tinned or bare copper strands.
Integral Insulation and JacketExtruded PVC, 80 mils minimum average thickness, 72 mils minimum thickness at any point, same as for Type SPT-3.
AssemblyThree conductors laid in parallel.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerating equipment or room air conditioners or room cooler units; or Internal wiring of electric refrigerating equipment or room air conditioners or room cooler units. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024