APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20360 Issued:1984-11-26
Revised:2012-03-21
Style 20360 Laminated or Extruded Flat Ribbon Cable

Rating80 deg C, 150 Vac, 300 Vac, Horizontal flame.
ConductorFlat, bare or plated with 6 mils minimum thickness, 10 mils maximum thickness.
InsulationExtruded PVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Extruded or heat laminated.
AssemblyTwo to five conductors. Minimum width of 40 mils and maximum width of 120 mils. Conductors may be straight or irregular shaped and laid parallel, spaced 5 mils minimum in one plane.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment and/or Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024