APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20362 Issued:1984-12-21
Revised:2011-10-05
Style 20362 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating150 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketECTFE
Dia of Cable Under Jacket in inchesminimum average thickness milsminimum at any point mils
0.425 or less2520
0.426 - 0.7003024
0.701 - 1.5004536
1.501 - 2.5006048
2.501 and larger8064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliances or electronic equipment. In addition, the tag may also indicate the following: 600 V peak, for electronic use only.

UL and the UL Logo are trademarks of UL LLC © 2024