APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20363 Issued:1984-12-21
Revised:2012-05-14
Style 20363 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating150 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid, paper, nylon, oriented polyethylene terephthalate, or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
JacketExtruded ECTFE
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inches or less30 mils24 mils
0.426-0.700 inch45 mils36 mils
0.701-1.500 inches55 mils44 mils
1.501-2.500 inches65 mils50 mils
2.501 inches and larger80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliances or electronic equipment. In addition, the tag may also indicate the following: 2500 V peak, for electronic use only.