APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20364 Issued:1984-12-21
Revised:2019-11-07
Style 20364 Multiple-conductor cable using non-integral jacket

Rating150 deg C, no voltage assigned, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure and having a min rating of 150 deg C. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
ShieldOptional.
ConductorTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
JacketECTFE
dia of the cable under jacket in inches
0.425 or less25 mils min average20 mils minimum at any point
0.426-0.700 dia30 avg24 min
0.701-1.500 dia45 avg36 min
1.501-2.500 dia60 avg48 min
2.501 dia and larger80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliances or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024