APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20366 Issued:1984-12-21
Revised:2012-04-24
Style 20366 Flat Cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 20 AWG solid or stranded round, tinned or bare copper.
InsulationPE, 5 mils min any point.
AssemblyTwo to 200 insulated singles laid parallel in one plane, bonded between the PVC covering in such a fashion to form a flat ribbon-type cable. May include mixed AWG sizes.
CoveringTwo laminated sheets or extruded PVC, 4 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024