APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2037 Issued:1959-05-01
Revised:2012-11-26
Style 2037 Parallel cable with extruded intergral insualtion and jacket

Rating60 deg C, 600 Vac, FT2 flame.
Conductor18 AWG or 16 AWG consisting of 30 AWG or smaller strands.
Integral Insulation and JacketExtruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
AssemblyTwo conductor, same as SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electric Refrigerators or Room Cooler Units where ripped not more than 15 inches. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024