APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20373 Issued:1985-01-22
Revised:2012-12-12
Style 20373 Multiconductor flat cable with extruded non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG - 18 AWG. One or more conductors covered with 3-40 mils conductive PVC or PE covering.
InsulationExtruded PVC, extruded PE, extruded FRPE, extruded foamed PVC, extruded foamed PE, extruded foamed FRPE, extruded XLPVC, extruded XLPE, extruded XLFRPE, extruded foamed XLPVC, extruded foamed XLPE or extruded foamed XLFRPE, 3 mils minimum thickness at any point, 40 mils maximum average thickness.
ShieldOptional.
AssemblyMaximum 10 conductors. Insulated conductors and conductive covered conductors laid parallel in one plane. At least one conductor must not have conductive coating. May include barrier layer or fillers.
JacketExtruded PVC, 3 mils minimum thickness at any point. 40 mils maximum average thickness. Optional - jacket may form web, maximum 0.250 inch width.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024