APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20374 Issued:1985-01-25
Revised:2012-07-13
Style 20374 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor38 AWG - 32 AWG tinned or bare copper, consisting of four strands each 2-4 mils diameter, twisted together, lay not specified. Each strand individually coated with polyurethane, approximately 0.1 - 0.3 mils thick. Each conductor (consisting of four individually coated strands) shall be coated with different color polyurethane.
InsulationPVC, 5 mils minimum average, 4 mils minimum at any point.
AssemblyThree or four conductors cabled together, lay not specified.
ShieldBraided or spiral wrap copper wires. Individual strands may be coated with polyurethane.
JacketPVC, 14 mils min average, 11 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of 30 V Class 2 circuits of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024